Pulse Pressure & Volume Replacement

Clinician's Brief (Capsule)

Sign in to Print/View PDF

Pulse pressure variation (PPV), a physiologic occurrence secondary to cyclic changes in cardiac stroke volume (SV) during mechanical positive pressure ventilation, is a useful parameter in predicting the likelihood of improving SV or cardiac output (CO) with IV fluid expansion. This prospective crossover study evaluated the effects of dexmedetomidine (DEX) on changes in PPV when hemorrhage was induced and followed by volume replacement (VR). The ypothesis was that DEX, a vasopressor, would cause a shift of blood flow from the periphery to the organs and minimize SV and changes in PPV.

Anesthesia was maintained in 8 adult dogs during treatments using isoflurane (ISO) either alone or in combination with a continuous rate infusion (CRI) of DEX. Baseline data were recorded for PPV and CO. Hemorrhage was induced by collection of 30% circulating blood volume over 3 consecutive stages. Cardiopulmonary data were again collected at each stage. Autologous blood was transfused back into each patient for VR in 3 stages, followed again by data collection at each stage. In 4 of 8 ISO dogs, hypovolemia caused hypotension. PPV increased as a result of decreased SV and normalized or increased with VR. In the ISO with DEX CRI protocol, systemic vascular resistance was noted in both the normotensive and previously hypotensive dogs; this prevented increases in PPV when hemorrhage was induced. These results indicate that in patients given DEX, PPV may mask hemorrhage and thus should not be used to guide VR.

Commentary

Several aspects of this study deserve comment: 1) There is a need for monitoring response to fluid volume loading, as was done in this study following hemorrhage. This could apply to any patient receiving fluid therapy because overhydration can contribute to patient morbidity.1 Although the authors used direct arterial blood pressure to determine PPV, there is evidence that plethysmography variability index using noninvasive pulse oximetry may also be useful in assessing fluid load2 and would clearly be more practical in most hospitals; 2) The a-2 mediated vasoconstriction that limited PPV assessment is not surprising, but note that dexmedetomidine was administered as a CRI at the highest end of the recommended dose. The more common method of using dexmedetomidine as a single, clinically appropriate dose for premedication is unlikely to impact PPV because the vasoconstriction dissipates fairly rapidly.—Tamara Grubb, DVM, PhD, DACVAA

References

For global readers, a calculator to convert laboratory values, dosages, and other measurements to SI units can be found here.

All Clinician's Brief content is reviewed for accuracy at the time of publication. Previously published content may not reflect recent developments in research and practice.

Material from Clinician's Brief may not be reproduced, distributed, or used in whole or in part without prior permission of Educational Concepts, LLC. For questions or inquiries please contact us.

Podcasts

Clinician's Brief:
The Podcast
Listen as host Alyssa Watson, DVM, talks with the authors of your favorite Clinician’s Brief articles. Dig deeper and explore the conversations behind the content here.
Clinician's Brief provides relevant diagnostic and treatment information for small animal practitioners. It has been ranked the #1 most essential publication by small animal veterinarians for 9 years.*

*2007-2017 PERQ and Essential Media Studies

© 2022 Educational Concepts, L.L.C. dba Brief Media ™ All Rights Reserved. Terms & Conditions | DMCA Copyright | Privacy Policy | Acceptable Use Policy